Working Voltage
(up to and including)

Nominal Ac Mains
Supply Voltage
<150V
(Mains Transient
Voltage 1500V)

Nominal Ac Mains
Supply Voltage
>150V <300V
(Mains Transient
Voltage 2500V)

Nominal Ac Mains Supply Voltage
>300V <600V
(Mains Transient
Voltage 4000V)
Peak or Dc Rms
(Sinusoidal)
Pollution
Degree 1 and 2

Pollution
Degree 3

Pollution
Degree 1 and 2
Pollution
Degree 3
Pollution
Degree 1 and 2

V

V

F

B/S

R

F

B/S

R

F

B/S

R

F

B/S

R

F

B/S

R

71 50 0.4 1.0
(0.5)

2.0
(1.0)

0.8 1.3
(0.8)
2.8
(1.6)
1.0 2.0
(1.5)
4.0
(3.0)
1.3

2.0
(1.5)

4.0
(3.0)
2.0 3.2
(3.0)
6.4
(8.0)
210 150 0.5 1.0
(0.5)
2.0
(1.0)
0.8 1.3
(0.8)
2.6
(1.8)
1.4 2.0
(1.5)
4.0
(3.0)
1.5 2.0
(1.5)
4.0
(3.0)
2.0

3.2
(3.0)

5.4
(6.0)
420 300 F 1.5 B/S 2.0 (1.5) R 4.0 (3.0) 2.5 3.2
(3.0)
6.4
(6.0)
840 600 F 3.0 B/S 3.2 (3.0) R 6.4 (8.0)
1400 1000 F/BS 4.2 R 6.4

2800
7000
9800
14,000
28,000
42,000

2000
5000
7000
10,000
20,000
30,000
F/B/S/R 8.4
F/B/S/R 17.5
F/B/S/R 25
F/B/S/R 37
F/B/S/R 80
F/B/S/R 130

1. The values in the table are applicable to functional (F), basic (B), supplementary (S), and reinforced (R) insulation.
2. The values in parentheses are applicable to basic, supplementary, or reinforced insulation only if manufacturing is subjected to a quality control program that provides at least the same level of assurance as the example given in annex R.2. In particular, double and reinforced insulation shall be subjected to routine tests for electric strength.
3. For working voltages between 2800 V peak or dc and 42,000 V peak or dc, linear interpolation is permitted between the nearest two points, the calculated spacing being rounded up to the next higher 0.1-mm increment.

Table I. Table 2H of the standard provides minimum clearances for insulation in primary circuits and between primary and secondary circuits (clearances in millimeters).