Working Voltage |
Nominal Ac Mains |
Nominal Ac Mains |
Nominal Ac Mains |
Circuit Not Subjet to Transient Overvoltage |
|||||||||||||||
|
Voltage Peak or Dc |
Voltage Rms |
Pollution |
Pollution |
Pollution |
Pollution |
Pollution |
Pollution |
||||||||||||
|
V |
V |
F |
B/S |
R |
F |
B/S |
R |
F |
B/S |
R |
F |
B/S |
R |
F |
B/S |
R |
F |
B/S |
R |
|
71 |
50 |
0.4 |
0.7 |
1.4 |
1.0 |
1.3 |
2.5 |
0.7 |
1.0 |
2.0 |
1.0 |
1.3 |
2.5 |
1.7 |
2.0 |
4.0 |
0.4 |
0.4 |
0.8 |
|
140 |
100 |
0.8 |
0.7 |
1.4 |
1.0 |
1.3 |
2.6 |
0.7 |
1.0 |
2.0 |
1.0 |
1.3 |
2.6 |
1.7 |
2.0 |
4.0 |
0.6 |
0.7 |
1.4 |
|
210 |
150 |
0.6 |
0.9 |
1.8 |
1.0 |
1.3 |
2.8 |
0.7 |
1.0 |
2.0 |
1.0 |
1.3 |
2.6 |
1.7 |
2.0 |
4.0 |
0.6 |
0.7 |
1.4 |
|
280 |
200 |
F 1.1 (0.8) B/S 1.4 (0.8) R 2.8 (1.6) |
1.7 |
2.0 |
4.0 |
1.1 |
1.1 |
2.2 |
|||||||||||
|
420 |
300 |
F 1.6 (1.0) B/S 1.9 (1.0) R 3.8 (2.0) |
1.7 |
2.0 |
4.0 |
1.4 |
1.4 |
2.8 |
|||||||||||
|
700 |
500 |
F/B/S 2.5 R 5.0 |
|||||||||||||||||
|
2800 |
2000 |
F/B/S/R 8.4 See2 |
|||||||||||||||||
|
1. Where transients in the equipment
exceed this value, the appropriate higher clearance shall be used.
If the clearance path is partly along the surface of a material that is not Material Group I, the electric strength test is conducted across the air gap only. |
|||||||||||||||||||
|
Table III. Table 2K of the standard provides minimum clearances in secondary circuits (clearances in millimeters). |
|||||||||||||||||||